EMC Rectification
Due to the fact that companies did not conduct electromagnetic compatibility (EMC) design or did not consider the design thoroughly during the product design stage, and the market's requirements for product electromagnetic compatibility (EMC) are becoming increasingly stringent. Companies often fail to pass some electromagnetic compatibility (EMC) projects during the process of product electromagnetic compatibility (EMC) certification, and need to find the root cause of the problem and solve the problem in a short period of time. In response to this problem of companies, Luxshare Testing can provide electromagnetic compatibility (EMC) rectification services to help companies solve electromagnetic compatibility (EMC) problems encountered during testing.


Several directions for solving product electromagnetic compatibility (EMC) problems

Provide solutions from the source (advantages: low cost. Disadvantages: affects product performance)

Provide anti-blocking solutions (advantages: does not affect product performance. Disadvantages: high cost)

Provide solutions that can be mass-produced (combining the above two solutions)

Provide low-cost solutions (optimized solutions)

The solutions provided fully consider product time schedule, production process, etc. (customize solutions according to specific circumstances)

Rectification services

Electromagnetic interference (EMI) problem rectification services

Electromagnetic anti-interference (EMS) problem rectification services

Rectification ideas

Luxshare detection rectification

Luxshare detection technology considers the overall situation from the perspective of product system, and solves the electromagnetic compatibility (EMC) problem of products from the source through detailed analysis of product schematics, PCB, and structure, ensuring that enterprises are provided with fast, efficient, low-cost, and mass-producible rectification solutions to maximize customer benefits.

Customers make their own rectifications, and Luxshare provides guidance.
Luxshare test engineers will demonstrate EMC problems from various combinations of laboratory test technology and instruments, find the source of the product's EMC problems, and then analyze the product schematic, PCB, and structure in detail for customers, so that customers can understand and solve EMC problems by themselves, and ensure that they provide enterprises with fast, efficient, low-cost, and mass-producible rectification solutions to maximize customer interests and allow customers to control product costs and EMC problems by themselves.

1. Project evaluation

Understand the problems currently encountered by the product during EMC testing, and formulate a quotation based on project evaluation.

Be familiar with product performance, working principles, etc., evaluate the difficulty of the project, and formulate a confidentiality agreement.

2. Contract signing

3. Survey and positioning

Locate the source of product interference. (If the customer makes a rectification, it can be demonstrated to the customer)

Locate the product interference path. (If the customer makes a rectification, it can be demonstrated to the customer)

Output survey and positioning rectification report;

4. Final Verification

Test the new prototype after the board modification;

Control the cost of the new prototype after the board modification;

Output the final verification test report;

After-sales service

After the cooperation is completed, free electromagnetic compatibility technology exchange and training services for the product;

Subsequently entrust Luxshare Testing Technology EMC testing cooperation, and a 10% discount on the testing fee will be given;

Daily telephone and email EMC consultation; including electromagnetic compatibility certification, design, rectification, etc.;

Free use of spectrum analyzer positioning technology services at Luxshare Testing Company, our company arranges engineers to provide guidance and give suggestions;

Rectification case

Customer: A well-known medical device company in Chengdu

Product: Low-temperature plasma sterilizer

Rectification: Radiation, conduction is not enough, ESD Introduction: The product is a low-temperature plasma sterilizer, which will generate high-voltage plasma, a three-phase motor to generate low temperature, an industrial computer, and a card reader. The radiation and conduction exceed the standard a lot, and it will shut down when EFT and ESD interfere. After opening the EUT, we got the schematic diagram and circuit diagram and analyzed them with the test instrument and found the following problems: 1. The high-voltage output of plasma produces great interference. 2. Several signal lines of the industrial computer have relatively large radiation problems. 3. The industrial computer is not grounded. Because the accessories are not produced by the customer, the customer cannot fix these accessories, so we use the following processing methods: shield the plasma high-voltage output line, add a magnetic ring to the output line of the industrial computer, ground the iron shell of the industrial computer, add a filter to the three-phase power input, and add a filter to the power input of the plasma high-voltage device. After the test, all EMC items are qualified.

Customer: A famous precision equipment company in Shenzhen

Product: Electrocardiograph radiation

Correction: ESD, EFT test computer data will be interrupted, and then the computer software will die. Introduction: It is a laptop equipped with an electrocardiograph, which is USB powered and communicated, and the software is processed on the laptop. Because the customer said that it will be used at home, it must pass CLASS B. After the test, it was found that the radiation, ESD, and EFT could not pass. When I saw the radiation data, I found that the data was a multiple of the USB communication frequency, so I classified the radiation problem into USB cables and USB ports. Then I changed the USB cable to a good one, added magnetic rings at both ends of the EUT and PC, and the radiation was tested. However, ESD and EFT were still the same, and the computer communication would be interrupted and the software would freeze. Later, I used the signal to detect and found that the crystal oscillator signal of the USB communication module of the electrocardiograph was very sensitive. Then I added a TVS tube to the crystal oscillator signal and the problem was solved.


Product Tags:

EMC Certification Services

      

Streamline EMC Certification

      

Luxshare Testing EMC Certification

      
Wholesale Streamline Your Product S EMC Certification With Luxshare Testing Services from china suppliers

Streamline Your Product S EMC Certification With Luxshare Testing Services Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen LCS Compliance Testing Laboratory Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)